IEC 60456 washing machine performance test system
Equipment Overview:
The equipment is Mainly used for washing machine performance test. The whole system is composed of water supply room, test room and control system. The equipment not only provides constant temperature and constant pressure water source for the test, but also records the relevant parameters of the test process in a timely manner, calculates and generates test reports. The water supply equipment has multiple water tanks. The tap water is purified and input into the hard water preparation tank. The hardness of the water is adjusted in the hard water preparation tank before being added to the water supply tank. Use cooling water tower) to make the water reach the test temperature, and the water can be supplied alternately. Press the water pump into the water supply pipeline, and then divide it into two channels for each test station in the test room. The test water is not recovered. The water supply room and the test room are partitioned by the thermal insulation library board, the test room is equipped with air conditioning; the ground is provided with a drainage ditch. The control cabinet is located indoors, the test instrument is installed at the test station, and the data is collected to the computer through the network. Insulation measures are adopted for the water tank and pipelines, and continuous circulation of water is used to ensure that the temperature fluctuation of the water inlet of the laboratory test station is not greater than 0.5℃ / min during the work.
Standards:
IEC60456"Clothes washing machines for household use - Methods for measuring the performance"
GBT 4288-2008 "Electric Washing Machines for Household and Similar Uses";
GB 4706.24-2008, 4706.26-2008 "Special Requirements for Safe Washing Machines for Household and Similar Uses";
GB 23118-2008 "Drum Type for Household and Similar Uses" Technical requirements for dryers and drum-type washing machines";
The main function
No.
|
Parts Name
|
Functional use
|
remarks
|
1
|
constant temperature room
|
Control the temperature in the test room so that the test can be performed in the environment required by the standard.
|
1 set
|
2
|
Original water tank
|
Tap water is used after purification, and the purified water can be used for hardness adjustment of test water or for other purposes.
|
1
|
3
|
Water quality purification device
|
1 set
|
4
|
raw water storage tank
|
1 pc
|
5
|
hard water preparation tank
|
By manually adjusting the hardness of the water to meet the test requirements, it is supplied to the water supply tank.
|
1
|
6
|
cold water supply tank
|
Supply test water below the ambient temperature.
|
2 alternate water supplies
|
7
|
hot water supply tank
|
Supply test water at a temperature above the ambient temperature.
|
2 alternate water supplies
|
8
|
test station
|
The connection ports for sample testing include test power interface, inlet and outlet interface, thermocouple interface, water pressure, flow and power meter. It can perform voltage adjustment, power supply selection, water source selection and various electrical connection tests.
|
12 (one of them with speed test and one with temperature test)
|
9
|
control and data collection system
|
Set test parameters, perform test operations, test data collection, data collation, report generation and historical data query.
|
1 set
|
|