Forced internal short circuit tester
Model: BND-200kg-225L
Overview:
The equipment is designed according to IEC62133 and other standards. It comprehensively tests three parameters of battery deformation, test voltage and pressure acquisition. It is controlled by Japanese Panasonic servo computer software.
IEC62133 purpose:
Impurities such as metal dust and scrap particles that may enter the manufacturing process during the manufacturing process, and the potential danger of internal short circuit caused by piercing the diaphragm between the positive and negative electrodes. Its test object is for cylindrical or prismatic cells. This test is currently only available in Korea, Japan, Switzerland and France.
Main technical parameters of temperature control box
1. Temperature range: -10 ° C ~ +100 ° C;
2. Resolution accuracy: Temperature: 0.01 ° C;
3. Temperature fluctuation: 0.5 ° C;
4. No-load temperature accuracy: 2.0 ° C;
5. Extreme low temperature: -10 ° C;
6. Heating rate: from -10 °C to +100 °C less than 40 min (non-linear no-load);
7. Cooling rate: from +20 °C to -10 °C less than 40 min (non-linear no-load);
8. Inner box size: W600 X H750 X D500 MM;
9. Inner box material: mirror stainless steel plate, bottom reinforcement;
10. Outer box size: W1170 X H1850 X D1020MM;
11. Outer box material: cold rolled steel paint treatment;
Main technical parameters of pressure test system
1. Maximum load: 200KG
2. Force value resolution: 1/10000;
3. Force accuracy: ≤0.5%;
4. Displacement resolution: 1/1000;
5. Displacement accuracy: ≤0.5%;
6. Speed range: 1 ~ 200mm / min;
7. Effective stroke: 150MM (without gripper);
8. Test the maximum plane: 200X200MM (special test width can also be customized according to customer needs);
9. Voltage acquisition range: 0 ~ 10V;
10. Voltage resolution: 1mv;
11. Voltage acquisition frequency: 100HZ;
12. Power supply: 220V 50HZ 3KW;
|