Product name
Model
|
Programmable constant temperature and humidity test chamber
BND-PTHW-12000B
|
Limit sample
|
The test equipment prohibits:
Flammable, explosive, volatile substances Specimen test or storage
Test or storage of corrosive substances
Test or storage of biological samples
Test or storage of samples of strong electromagnetic emission sources
|
Volume, size and weight:
|
2.1. Nominal volume
2.2. Inner box size
2.3. Dimensions
2.4. Weight
2.5.door
|
12000L
W3000 X H2000 x D2000mm
W4000 X H2300 x D2200mm
About: 2000 kg.
Large inspection glass door box single open W800 × H1800 mm
|
performance
|
Testing conditions
|
Ambient temperature of +25 oC, relative humidity ≤ 85%, test chamber without sample conditions
|
Testing method
|
GB/T 5170.2-1996 temperature testing
|
Temperature range
|
-20oC→+85oC
|
temperature fluctuation
|
±0.5oC
|
Temperature deviation
|
±2.0oC
|
Humidity range
|
20%~98%R.H
|
humidity fluctuation
|
±2.5%R.H.
|
humidity uniformity
|
75%±3.0% 75%±5.0%.
|
Temp.rising speed
|
+10oC→+80oC 25 min nonlinearity(loaded).
|
Temp.falling speed
|
1oC/ min nonlinearity(loaded,The control system is automatically adjusted)
|
standards
|
IEC68-2-1 test A:
IEC68-2-2 test B:
|