Three box-type Thermal shock Test Chamber
Purpose:
It is necessary test equipment for the aerospace, automotive, home
appliances, research and other fields, used for examination and identification
of parameters, performance and the use of adaptive of electrical, electronics,
automotive electronics, materials and other products, after making high and low
temperature impact test. Applied to schools, factories, military, research, and
other organizations
Product Spec.and
Technical parameter table
|
model
|
BND-HLR3-80
|
BND-HLR3-100
|
BND-HLR3-150
|
performance
|
Preheat room
|
Upper limit preheat
temperature
|
200oC
|
Heating time
|
﹢20~﹢200oC≈20min
|
Precool room
|
Lower limit precool
temperature
|
﹣75oC
|
Cooling time
|
﹢20~﹣70oC≈80min
|
Workroom
|
Temperature shock range
|
(-55oC~-10)~(50~﹢150oC)
|
Temperature fluctuation
|
≤±0.5oC
|
Temperature deviation
|
≤±2oC
|
Temperature revert time
|
≤5min
|
Temperature revert
conditions
|
CJ602S3Ⅰ
|
Condition 1
|
sample load: 10kg
with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 10kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
CJ602S3Ⅱ
|
Condition 1
|
sample load: 20kg
with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 20kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
Condition 3
|
sample load: 7.5kg
with plastic package IC;sample exposed:
30min in ﹢150oC,30min in ﹣55oC
|
CJ603S3Ⅰ
|
Condition 1
|
sample load: 10kg with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 10kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
CJ603S3Ⅱ
|
Condition 1
|
sample load: 20kg
with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 20kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
Condition 3
|
sample load: 10kg
with plastic package IC;sample exposed:
30min in ﹢150oC,30min in ﹣55oC
|
CJ605S3Ⅰ
|
Condition 1
|
sample load: 10kg
with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 10kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
CJ605S3Ⅱ
|
Condition 1
|
sample load: 20kg
with plastic package IC;sample exposed:
30min in ﹢125oC,30min in ﹣40oC
|
Condition 2
|
sample load: 20kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,5min in ambient temp,30min in ﹣55oC
|
Condition 3
|
sample load: 10kg
with plastic package IC;sampl exposed
:30min in ﹢150oC,30min in ﹣55oC
|
construction
|
shell
|
cooling steel
plate,surface spray
|
inner
|
steel plate
|
refrigeration
|
insulate
|
Rigid Polyurethane
Foam+extra-fine glass-wool
|
mode
|
cascade refrigerating
compressor
|
compressor
|
import compressor
|
Cable port(mm)
|
one on left side Φ50
|
Controller
|
color LCD touchscreen
display
|
recording equipment
|
temperature
recorder(optional)
|
communication Interface
|
RS485 interface,RS232
interface
|
Workroom dimensions(mm)
|
D
|
400
|
400
|
500
|
W
|
500
|
500
|
600
|
H
|
400
|
500
|
500
|
Exterior dimensions(mm)
|
D
|
2500
|
2700
|
2900
|
W
|
1000
|
1000
|
1130
|
H
|
1950
|
2000
|
2100
|
Installed power(KW)
|
Ⅰ
|
35
|
48
|
50
|
Ⅱ
|
46
|
56
|
56
|
Power Supply
|
AC380V 50Hz Three-phase
four-wire + protective earth wire
|
Standard Configuration
|
A copy of the
instruction and test report for the product, A certificate and quality
assurance.2 Shelf and 4 shelves .
|
Standards Applied
|
GJB150.5
|
|
|
|
|
|
|
|
|
|
|